Auxiliary installations

Apart from a wide range of mechanical seals offered by ANGA, we also provide our Customers with auxiliary installations, without which some applications for many seals would not be possible. At present, adapting to our Customers’ needs, we mainly offer auxiliary installations according to the four Plans described in the API 682: 23, 52, 53A, 53B and 74. On the Customer’s request we can deliver installations adapted to other API Plans. Installations and their components are selected individually, in accordance with the Customer’s requirements and the nature of the sealed process.

API Plan 32

Flushing liquid is supplied to the stuffing box from an external source of clean liquid. Attention should be paid to select the proper seal flushing…

API Plan 51

“Blind” stuffing box, the solution with an external tank, in order to form no-flow liquid protection (hydraulic lock) fed to the connection on the external…

API Plan 52

Application of external unpressurized tank for feeding buffer liquid to external unpressurized double sealing system. During normal operation the circulation is forced and maintained with…

API Plan 53a

Application of pressurized barrier liquid external tank to feed clean liquid to the gland box; circulation is forced and maintained by internal pumping ring (or…

API Plan 53b

Plan 53B differs from Plan 53A in that in the seal circuit pressure is maintained due to the application of external pressurized barrier liquid diaphragm…

API Plan 54

External, pressurized barrier liquid system is used to feed clean liquid to the double system external seal. Circulation is maintained by an external pump or…

API Plan 61

In this system only threaded holes of connection in the seal cover are provided for possible use by the purchaser. Typical application of this system…

API Plan 62

Installation of liquid or gas flow behind the seal. Application of quenching from an external source (vapour, gas, liquid) to remove deposits, which may be…

API Plan 71

Threaded connections to be used by the purchaser. Typically it is used when the purchaser may in the future use buffer (quenching) gas.